{"id":9070,"date":"2025-08-29T14:23:51","date_gmt":"2025-08-29T06:23:51","guid":{"rendered":"https:\/\/ascendas-asia.com\/?page_id=9070"},"modified":"2025-08-29T14:23:51","modified_gmt":"2025-08-29T06:23:51","slug":"transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool","status":"publish","type":"page","link":"https:\/\/ascendas-asia.com\/vi\/customer-stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/","title":{"rendered":"Transpower Ensures Reliability of New Zealand National Grid with Reserve Management Tool"},"content":{"rendered":"<h1 style=\"text-align: center; font-weight: bold;\">Transpower Ensures Reliability of New Zealand National Grid with Reserve Management Tool<\/h1>\n<table style=\"width: 100%; border-collapse: collapse; table-layout: fixed; border: 1px solid #99acc2; height: 1379.08px;\">\n<tbody>\n<tr style=\"height: 1379.08px;\">\n<td style=\"width: 39.6308%; padding: 4px; border-width: 0px; border-style: hidden; vertical-align: top; height: 1379.08px;\">\n<div><em>\u201cWe record frequencies on the grid, inject them into our Simulink model, and compare the simulation results to the actual system response. With Simulink we can continually calibrate and improve our model, and ultimately improve the accuracy of our reserve estimates.\u201d<\/em><\/p>\n<p><em>&nbsp;Heidi Heath, Transpower<\/em><\/div>\n<div>&nbsp;<\/div>\n<p><span style=\"font-weight: bold;\">Challenge<\/span><\/p>\n<p>Calculate the amount of reserve power needed to ensure that New Zealand\u2019s national grid can continue to operate if a generator fails<\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-weight: bold;\">Solution<\/span><\/p>\n<p>Use Simulink to run simulations of the entire grid, including generators, loads, and HVDC links, every 30 minutes<\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-weight: bold;\">Results<\/span><\/p>\n<ul>\n<li>Critical updates rapidly implemented<\/li>\n<li>Simulations verified using real data<\/li>\n<li>Updates made in-house<\/li>\n<\/ul>\n<p><\/p>\n<figure>\n<div>\n<div>&nbsp;<\/div>\n<\/div>\n<\/figure>\n<\/td>\n<td style=\"width: 60.3692%; padding: 4px; border-style: hidden; border-width: 1px; height: 1379.08px; vertical-align: top;\">\n<p>&nbsp;<\/p>\n<div>\n<div>\n<div>\n<div>\n<div>\n<figure style=\"text-align: center;\"><img decoding=\"async\" src=\"https:\/\/www.mathworks.com\/company\/user_stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/_jcr_content\/imageEnhancedParsys\/image.adapt.full.medium.jpg\/1469941285091.jpg\" alt=\"\" width=\"500\" height=\"281\" sizes=\"auto, (min-width: 1200px) 1140px, (min-width: 992px) 940px, calc(100vw - 30px)\" loading=\"lazy\" srcset=\"https:\/\/www.mathworks.com\/company\/user_stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/_jcr_content\/imageEnhancedParsys\/image.adapt.150.medium.jpg\/1469941285091.jpg 150w, https:\/\/www.mathworks.com\/company\/user_stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/_jcr_content\/imageEnhancedParsys\/image.adapt.320.medium.jpg\/1469941285091.jpg 320w, https:\/\/www.mathworks.com\/company\/user_stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/_jcr_content\/imageEnhancedParsys\/image.adapt.480.medium.jpg\/1469941285091.jpg 480w, https:\/\/www.mathworks.com\/company\/user_stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/_jcr_content\/imageEnhancedParsys\/image.adapt.620.medium.jpg\/1469941285091.jpg 620w, https:\/\/www.mathworks.com\/company\/user_stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/_jcr_content\/imageEnhancedParsys\/image.adapt.full.medium.jpg\/1469941285091.jpg 640w\" data-aem-src=\"\/content\/dam\/mathworks\/mathworks-dot-com\/cmsimages\/images\/user-stories\/q-z\/73622_responsive_User_Story_thumbnail_640x360_Transpower.jpg\" style=\"margin-left: auto; margin-right: auto; width: 500px; height: auto; max-width: 100%; display: block;\"><figcaption>Transmission lines near Transpower\u2019s Benmore substation.<\/figcaption><\/figure>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div>\n<div>\n<div>\n<p>Transpower owns and operates the New Zealand national grid, a high-voltage transmission network that delivers power to industrial, business, farming, and domestic electricity consumers. Transpower must balance load and generation to keep the grid\u2019s frequency at 50 Hz. If one generator fails, power from other generators must be made available within a few seconds to offset the loss and ensure the system frequency doesn\u2019t fall to a level from which recovery is not possible.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div>\n<div>\n<div>\n<p>Because it is costly to hold generated power in reserve, Transpower must precisely calculate the minimum reserve needed to ensure the reliability of the grid within established risk tolerances.<\/p>\n<p>To meet this need, Transpower has developed the Reserve Management Tool (RMT) in MATLAB<sup>\u00ae<\/sup><span>&nbsp;<\/span>and Simulink<sup>\u00ae<\/sup>. RMT includes a sophisticated model of the entire grid, including generators, loads, and high-voltage direct current (HVDC) links between New Zealand\u2019s two main islands. Simulations based on up-to-the-minute grid information are run every half hour to determine the currently needed reserve.<\/p>\n<p>\u201cTranspower has two directives. One is to make sure the lights stay on by operating the grid reliably, and the other is to do this economically,\u201d says Heidi Heath, investigations engineer at Transpower. \u201cBy driving Simulink simulations with real-world data, we not only make better tradeoffs between cost and reliability, we actually reduce costs while improving service.\u201d<\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<h2 style=\"font-weight: bold;\">Challenge<\/h2>\n<div>\n<div>\n<div>\n<p>In the past, Transpower used spreadsheets to calculate the required minimum reserve. This approach required a technician to perform numerous manual steps and run several supporting scripts. The system was inflexible, making it difficult to incorporate new generators as they came on line. Transpower needed a reserve management tool that could be updated rapidly as the grid changed.<\/p>\n<p>\u201cOver time, we needed to comply with more and more sophisticated rules to handle contingent events, and the cost pressures increased the need to estimate required reserve more accurately,\u201d says Heath. \u201cWe anticipated adding more generators, as well as making changes to the HVDC links. We needed a tool that we could adapt in-house so that we would not need to wait for a third-party company to make these changes.\u201d<\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<h2 style=\"font-weight: bold;\">Solution<\/h2>\n<div>\n<div>\n<div>\n<p>Using MATLAB and Simulink, Transpower built a new RMT to model and simulate New Zealand\u2019s entire national grid.<\/p>\n<p>Transpower engineers created MATLAB and Simulink models of wind, hydroelectric, and geothermal plants, which make up most of the generators on the grid. The individual plant models use the input frequency and proportional-integral-derivative (PID) controllers to calculate power output. The PID controller gains were tuned using Control System Toolbox\u2122.<\/p>\n<p>To develop Simulink models for the more advanced combined-cycle thermal plants, Transpower used block diagrams and test data provided by the companies operating the plants.<\/p>\n<p>The engineers also developed models for more than 30 interruptible and non-interruptible loads distributed across the country\u2019s two main islands, as well as for the HVDC links that connect the islands.<\/p>\n<p>Working in Simulink, engineers assembled a complete model of the grid with models of the loads, HVDC links, and approximately 80 generators.<\/p>\n<p>Using MATLAB Compiler\u2122 and Simulink Coder\u2122, the team created a standalone executable of the complete model. The Transpower IT team integrated the model with a Scheduling Price Dispatch (SPD) tool, which is used to procure the required reserve at the lowest price.<\/p>\n<p>The new RMT tool is currently run every 30 minutes to calculate the required reserve.<\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<h2 style=\"font-weight: bold;\">Results<\/h2>\n<div>\n<div>\n<div>\n<ul>\n<li><strong>Critical updates rapidly implemented<\/strong>. \u201cWhen a new generator is added or some other change is made to the grid, we need to update RMT quickly,\u201d says Heath. \u201cOver the past year, we\u2019ve made 18 such updates in Simulink, which would have been more difficult and less accurate with our spreadsheet-based system.\u201d<\/li>\n<li><strong>Simulations verified using real data<\/strong>. \u201cWhen a system event occurs, we can drive our Simulink model with measured data, see if RMT predicted results accurately, and verify that the generators responded as expected,\u201d says Heath. \u201cThis approach enables us to improve the accuracy of our grid model and individual generator models, and it helps us identify possible grid improvements.\u201d<\/li>\n<li><strong>Updates made in-house<\/strong>. \u201cWith MATLAB and Simulink, we can make changes to the system using our own expertise instead of having to rely on an outside vendor,\u201d says Heath. \u201cAs a result, we have full control over when the updates will be completed, as well as control over sensitive data.\u201d<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: center;\">&nbsp;<\/p>\n<p style=\"text-align: center;\"><span style=\"font-weight: normal;\"><a class=\"maxbutton-1 maxbutton maxbutton-get-quote\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/ascendas-asia.com\/vi\/contact-us\/\"><span class='mb-text'>Get Quote<\/span><\/a>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<a class=\"maxbutton-3 maxbutton maxbutton-download-a-free-trial\" target=\"_blank\" rel=\"noopener\" href=\"https:\/\/ascendas-asia.com\/vi\/free-matlab-trial\/\"><span class='mb-text'>Download a FREE Trial<\/span><\/a><\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>Transpower Ensures Reliability of New Zealand National Grid with Reserve Management Tool \u201cWe record frequencies on the grid, inject them into our Simulink model, and compare the simulation results to the actual system response. With Simulink we can continually calibrate and improve our model, and ultimately improve the accuracy of our reserve estimates.\u201d &nbsp;Heidi Heath, [&hellip;]<\/p>","protected":false},"author":43,"featured_media":0,"parent":3677,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"content-type":"","footnotes":"","_links_to":"","_links_to_target":""},"class_list":["post-9070","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v22.1 (Yoast SEO v27.7) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Transpower Ensures Reliability of New Zealand National Grid with Reserve Management Tool - TechSource Systems &amp; Ascendas Systems Group<\/title>\n<meta name=\"description\" content=\"Transpower calculated the amount of reserve power needed to ensure that the New Zealand&#039;s entire grid can continue to operate if a generator fails.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ascendas-asia.com\/vi\/customer-stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/\" \/>\n<meta property=\"og:locale\" content=\"vi_VN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Transpower Ensures Reliability of New Zealand National Grid with Reserve Management Tool\" \/>\n<meta property=\"og:description\" content=\"Transpower calculated the amount of reserve power needed to ensure that the New Zealand&#039;s entire grid can continue to operate if a generator fails.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ascendas-asia.com\/vi\/customer-stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/\" \/>\n<meta property=\"og:site_name\" content=\"TechSource Systems &amp; Ascendas Systems Group\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/techsourcesystems\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.mathworks.com\/company\/user_stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/_jcr_content\/imageEnhancedParsys\/image.adapt.full.medium.jpg\/1469941285091.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u01af\u1edbc t\u00ednh th\u1eddi gian \u0111\u1ecdc\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 ph\u00fat\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/ascendas-asia.com\\\/customer-stories\\\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\\\/\",\"url\":\"https:\\\/\\\/ascendas-asia.com\\\/customer-stories\\\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\\\/\",\"name\":\"Transpower Ensures Reliability of New Zealand National Grid with Reserve Management Tool - TechSource Systems &amp; Ascendas Systems Group\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ascendas-asia.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/ascendas-asia.com\\\/customer-stories\\\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/ascendas-asia.com\\\/customer-stories\\\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.mathworks.com\\\/company\\\/user_stories\\\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\\\/_jcr_content\\\/imageEnhancedParsys\\\/image.adapt.full.medium.jpg\\\/1469941285091.jpg\",\"datePublished\":\"2025-08-29T06:23:51+00:00\",\"description\":\"Transpower calculated the amount of reserve power needed to ensure that the New Zealand's entire grid can continue to operate if a generator fails.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ascendas-asia.com\\\/customer-stories\\\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\\\/#breadcrumb\"},\"inLanguage\":\"vi\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/ascendas-asia.com\\\/customer-stories\\\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"vi\",\"@id\":\"https:\\\/\\\/ascendas-asia.com\\\/customer-stories\\\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.mathworks.com\\\/company\\\/user_stories\\\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\\\/_jcr_content\\\/imageEnhancedParsys\\\/image.adapt.full.medium.jpg\\\/1469941285091.jpg\",\"contentUrl\":\"https:\\\/\\\/www.mathworks.com\\\/company\\\/user_stories\\\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\\\/_jcr_content\\\/imageEnhancedParsys\\\/image.adapt.full.medium.jpg\\\/1469941285091.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ascendas-asia.com\\\/customer-stories\\\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/ascendas-asia.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Customer Stories\",\"item\":\"https:\\\/\\\/ascendas-asia.com\\\/customer-stories\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Transpower Ensures Reliability of New Zealand National Grid with Reserve Management Tool\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/ascendas-asia.com\\\/#website\",\"url\":\"https:\\\/\\\/ascendas-asia.com\\\/\",\"name\":\"TechSource Systems & Ascendas Systems Group | MathWorks Authorized Reseller\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/ascendas-asia.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/ascendas-asia.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"vi\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/ascendas-asia.com\\\/#organization\",\"name\":\"TechSource Systems & Ascendas Systems Group\",\"url\":\"https:\\\/\\\/ascendas-asia.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"vi\",\"@id\":\"https:\\\/\\\/ascendas-asia.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/ascendas-asia.com\\\/wp-content\\\/uploads\\\/2021\\\/12\\\/logo.jpg\",\"contentUrl\":\"https:\\\/\\\/ascendas-asia.com\\\/wp-content\\\/uploads\\\/2021\\\/12\\\/logo.jpg\",\"width\":825,\"height\":131,\"caption\":\"TechSource Systems & Ascendas Systems Group\"},\"image\":{\"@id\":\"https:\\\/\\\/ascendas-asia.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/techsourcesystems\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/techsource-systems\\\/\",\"https:\\\/\\\/www.youtube.com\\\/c\\\/TechSourceSystems\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Transpower Ensures Reliability of New Zealand National Grid with Reserve Management Tool - TechSource Systems &amp; Ascendas Systems Group","description":"Transpower calculated the amount of reserve power needed to ensure that the New Zealand's entire grid can continue to operate if a generator fails.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ascendas-asia.com\/vi\/customer-stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/","og_locale":"vi_VN","og_type":"article","og_title":"Transpower Ensures Reliability of New Zealand National Grid with Reserve Management Tool","og_description":"Transpower calculated the amount of reserve power needed to ensure that the New Zealand's entire grid can continue to operate if a generator fails.","og_url":"https:\/\/ascendas-asia.com\/vi\/customer-stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/","og_site_name":"TechSource Systems &amp; Ascendas Systems Group","article_publisher":"https:\/\/www.facebook.com\/techsourcesystems","og_image":[{"url":"https:\/\/www.mathworks.com\/company\/user_stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/_jcr_content\/imageEnhancedParsys\/image.adapt.full.medium.jpg\/1469941285091.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u01af\u1edbc t\u00ednh th\u1eddi gian \u0111\u1ecdc":"4 ph\u00fat"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ascendas-asia.com\/customer-stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/","url":"https:\/\/ascendas-asia.com\/customer-stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/","name":"Transpower Ensures Reliability of New Zealand National Grid with Reserve Management Tool - TechSource Systems &amp; Ascendas Systems Group","isPartOf":{"@id":"https:\/\/ascendas-asia.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ascendas-asia.com\/customer-stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/#primaryimage"},"image":{"@id":"https:\/\/ascendas-asia.com\/customer-stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mathworks.com\/company\/user_stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/_jcr_content\/imageEnhancedParsys\/image.adapt.full.medium.jpg\/1469941285091.jpg","datePublished":"2025-08-29T06:23:51+00:00","description":"Transpower calculated the amount of reserve power needed to ensure that the New Zealand's entire grid can continue to operate if a generator fails.","breadcrumb":{"@id":"https:\/\/ascendas-asia.com\/customer-stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/#breadcrumb"},"inLanguage":"vi","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ascendas-asia.com\/customer-stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/"]}]},{"@type":"ImageObject","inLanguage":"vi","@id":"https:\/\/ascendas-asia.com\/customer-stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/#primaryimage","url":"https:\/\/www.mathworks.com\/company\/user_stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/_jcr_content\/imageEnhancedParsys\/image.adapt.full.medium.jpg\/1469941285091.jpg","contentUrl":"https:\/\/www.mathworks.com\/company\/user_stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/_jcr_content\/imageEnhancedParsys\/image.adapt.full.medium.jpg\/1469941285091.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/ascendas-asia.com\/customer-stories\/transpower-ensures-reliability-of-new-zealand-national-grid-with-reserve-management-tool\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ascendas-asia.com\/"},{"@type":"ListItem","position":2,"name":"Customer Stories","item":"https:\/\/ascendas-asia.com\/customer-stories\/"},{"@type":"ListItem","position":3,"name":"Transpower Ensures Reliability of New Zealand National Grid with Reserve Management Tool"}]},{"@type":"WebSite","@id":"https:\/\/ascendas-asia.com\/#website","url":"https:\/\/ascendas-asia.com\/","name":"TechSource Systems & Ascendas Systems Group | MathWorks Authorized Reseller","description":"","publisher":{"@id":"https:\/\/ascendas-asia.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ascendas-asia.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"vi"},{"@type":"Organization","@id":"https:\/\/ascendas-asia.com\/#organization","name":"TechSource Systems & Ascendas Systems Group","url":"https:\/\/ascendas-asia.com\/","logo":{"@type":"ImageObject","inLanguage":"vi","@id":"https:\/\/ascendas-asia.com\/#\/schema\/logo\/image\/","url":"https:\/\/ascendas-asia.com\/wp-content\/uploads\/2021\/12\/logo.jpg","contentUrl":"https:\/\/ascendas-asia.com\/wp-content\/uploads\/2021\/12\/logo.jpg","width":825,"height":131,"caption":"TechSource Systems & Ascendas Systems Group"},"image":{"@id":"https:\/\/ascendas-asia.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/techsourcesystems","https:\/\/www.linkedin.com\/company\/techsource-systems\/","https:\/\/www.youtube.com\/c\/TechSourceSystems"]}]}},"_links":{"self":[{"href":"https:\/\/ascendas-asia.com\/vi\/wp-json\/wp\/v2\/pages\/9070","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ascendas-asia.com\/vi\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ascendas-asia.com\/vi\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ascendas-asia.com\/vi\/wp-json\/wp\/v2\/users\/43"}],"replies":[{"embeddable":true,"href":"https:\/\/ascendas-asia.com\/vi\/wp-json\/wp\/v2\/comments?post=9070"}],"version-history":[{"count":3,"href":"https:\/\/ascendas-asia.com\/vi\/wp-json\/wp\/v2\/pages\/9070\/revisions"}],"predecessor-version":[{"id":9074,"href":"https:\/\/ascendas-asia.com\/vi\/wp-json\/wp\/v2\/pages\/9070\/revisions\/9074"}],"up":[{"embeddable":true,"href":"https:\/\/ascendas-asia.com\/vi\/wp-json\/wp\/v2\/pages\/3677"}],"wp:attachment":[{"href":"https:\/\/ascendas-asia.com\/vi\/wp-json\/wp\/v2\/media?parent=9070"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}